The AMPAC USA Commercial Reverse Osmosis 6000 GPD / 22,750LPD|APRO6000 is the result of 28 years of experience with the needs and requirements of commercial pure water users. The key factors are reliability, serviceability, and consistent performance with minimum user intervention are achieved in the solid design of the AMPAC USA Reverse Osmosis Systems.
Standard Features:
Frame |
Powder Coated One Piece Aluminum w/Diamond Plate |
Membranes |
(4) ea TFC 4″ x 40″ |
Vessels |
4″ x 40″ Stainless Steel or FRP |
Pump |
Goulds Multi Stage Jet Pump with Safeguards (SS option) |
Gauges – Glycerin |
Pre-Filter PSI, Post-Filter PSI, Booster Pump PSI |
Valves |
System Pressure, Recycle Pressure |
Switches |
Low PSI Cutout, Tank Full Cutout |
Electrical |
110 or 220 V, 50 or 60 Hz, 1 phase or 3 phase |
Motor |
2 Hp – 1725 rpm |
Connections |
1″ Quick Tubing Connectors |
Capacity per Gallon |
4.2 gal per min – 6,000 gals per day |
Capacity per Liters |
15.8 Liters per min – 22,750 Liters per day |
Operating Pressure |
170 – 225 psi |
Typical Recovery |
33% – 75% |
Typical Rejection |
99% |
Max Feed TDS |
2500 ppm – 15 grains For Municipal Water Design |
Max Feed TDS – |
10,000 ppm – 25 grains For Brackish Water Design |
Max Feed Temp |
113 degrees F |
Feed pH Range |
2-11 |
Max Chlorine |
less than 0.1 ppm |
Dimensions |
22″ wide x 22″ deep x 57″ ht. |
Weight |
180 Lbs. / 82 Kgs. |
Make of System: Fully Automated Turnkey Water Purification System including pre-treatment Modules and Reverse Osmosis System fully built on a Powder Coated Welded Aluminum Skid with Diamond Plate Base using good industrial practice and following manufacturer’s guidelines for every component.
Make of System: AP6000
Origin: Made in USA
Backwash & Regenerations Cycle: Ion Exchange System Cycle on Metered Basis, Multimedia System Cycle on Timer Basis and can be Adjustable up to 120 Minutes at any given time.
Delivery Terms: System is ready to be crated and shipped, on average 2-3 Weeks from the day of receipt of purchase order.
System production is based on the following conditions: 10,000ppm NaCI feed water, 77°f/ 25°c Operating temperature and 3.0-11.0pH Range. Actual feed water analysis may require special consideration affecting final design and pricing.
*Prices are subject to change without notice.
Provide customers with high quality products, solutions and services to
achieve the common success of enterprises and employees.